POSTED JUN 09, 2019
LENGTH 1:01:48

EPISODE LINK – CLICK / TAP TO LISTEN
SYNOPSIS:
Local Hive Report, Protective masks, Desirable Traits, UHU POR Glue, Brooklyn Bee Gate, Knocking Bees off of a Frame
EPISODE GUIDE
Agenda
- 00:00 – 00:23 | Opening: Opening Music
– Huey Lewis and the News - 00:23 – 02:21 | Welcome and Intro:
Welcoming Remarks & Agenda - 02:21 – 16:41 | Topic “0″: Local Hive
Report - 16:41 – 38:30 | Topic 1: Protective
Masks - 38:30 – 47:32 | Topic 2: Traits
Roundtable
- 00:00 – 52:21 | Roundtable 1: UHU POR Glue
for Polystyrene Hives - 52:21 – 54:55 | Roundtable 2: Brooklyn
Bee Gate - 54:55 – 60:26 | Roundtable 3: Knocking
bees off a frame follow up - 60:26 – 61:48 | Closing Comments
EPISODE LINKS
- Link | 3M cartridge and filter
selection Guide - Link | 3M Respirator Selection Guide
– Formic Acid Page 61 of 127, Oxalic Acid Page 89 of 127 - Link | History of Bees (Scroll down
to the breeding section) - Link | Sunset Park Brooklyn Honey Bee
Sculpture Gate
3M Mask Model – 3M 6503QL/49493 (see updates below)
3M Cartridges – 6006
3M Particulate Filters – Code N95
3M Filter Retainers – 3m 501 Pre-Filter Retainers (hold particulate filters)
See Updates about mask and cartridges below.
RESPIRATORS (Half Mask)
The 3M model listed above, 3M 6503QL/49493, is suitable for Oxalic Acid Vaporization treatments. There is a second option in the 3M Reusable Respirator Half Facepiece 7503 (LINK). The masks differ in their application.
– The first one is meant for construction spaces, where rugged durable masks are used.
– The second one uses silicone for the material and is suitable for extended wear in cleaner or controlled environments (vs. construction, grinding, welding, etc.)
CARTRIDGES
The cartridges noted above, and in this episode, are rated for Organic Acids and Acid Gases. They are not specifically listed for Oxalic Acid. They are compatible to be paired with a N95 filter which filters out particulates.
They are not considered the right cartridge for Oxalic Acid as they are not rated for Oxalic.
3M recommends a different model cartridge – the 3M P100 Respirator Cartridge/Filter 60923. This cartridge is suitable for both Organic Acids and Acid Gases, as well as particulates.
The P100 component is superior at filtering particulates, and the 60923 cartridge will work for both Oxalic Acid Vaporizations and applications that involve Formic Acid
Podcast: Play in new window | Download